QF-2A Gas Cylinder Valve
1 / 3
The QF-2A is a handwheel-operated cylinder valve for carbon dioxide service. It provides manual opening and closing at the cylinder.
The inlet, outlet and cone sealing interface are defined for connection matching. Review the specifications below when selecting the valve for your cylinder and connected equipment.
Key advantages
- Manual shut-off — Handwheel operation for opening and closing at the cylinder.
- CO₂ service — A model identified for carbon dioxide cylinder applications.
- Defined sealing interface — Cone connection details support checking the mating seal.
- Connection matching — Separate inlet and outlet designations support cylinder and equipment selection.
Print / Save PDF — no form required.
Specifications
| Parameter | Value |
|---|---|
| Applicable medium | Carbon dioxide |
| Working pressure | 15 MPa |
| Gas-tightness test pressure | 18 MPa |
| Proof test pressure | 33.75 MPa |
| Safety device | 22.5 MPa |
| Cylinder / inlet connection | PZ27.8(25E) |
| Outlet connection | G5/8-14-RH-EXT |
| Connection sealing form | 60° cone seat |
| Valve structure | Pressure-sealed design |
| Body material | HPb59-1 |
| Seal material | Nylon 1010 |
| Stem material | HPb59-1 |
| Handwheel material | ZL102 |
| Temperature range | -40 °C to 60 °C |
| Manufacturing standard / reference | GB/T 15382 |
Technical Illustration
For reference. Not to scale.
Product Configurator
| Model | Gas | Working pressure | Operation / structure | Inlet | Outlet | Sealing |
|---|---|---|---|---|---|---|
| QF-2A | Carbon dioxide | 15 MPa | Pressure-sealed design | PZ27.8(25E) | G5/8-14-RH-EXT | 60° cone seat |
| Your request |
Special requirements are subject to technical confirmation. Your requests do not change the standard product specifications.
Company catalogue
No approved company catalogue is currently available. You can request specific product documents through Technical Matching.
Need this product’s specifications? Print / Save PDF — no form required.
Connect with an Expert
Regarding: QF-2A · Carbon dioxide · 15 MPa
Our latest insights
Technical Article
Managing specification revisions during sourcing
Read more →Technical Article
Reading certification claims: scope and evidence
Read more →Technical Article
Working pressure, test pressure and other ratings: what to verify
Read more →Technical Article
Material and seal information to confirm with a supplier
Read more →Technical Article
Start with the application: building a valve requirements brief
Read more →Technical Article